DMR Power Supplies for Ships and Submarines

P/N 26004-1

DMR Power Supply for Ships, Submarines, and Ground

The Single Phase 60-400 Hz 115 VAC input version contains active Power Factor Correction, and produces +28 VDC @ 32A, +/-15 VDC @ 1A, +5 VDC @ 5A, and -220 VDC @ .02A, for a total output power of approximately 1180 W at 79% efficiency.

Technical Specifications

AC Electrical Power:

103 VAC to 126 VAC, 1 phase, 45 to 420 Hz

Power Factor:

60 Hz: 0.998; 400 Hz: 0.95

Worst Case Voltage:

92 VAC, 2 seconds; 138 VAC, 2 seconds

Voltage Spike:

1000 V, 50 uSec impulse

Emergency Condition Voltages:

Type I power (60 Hz): 155 VAC, 2 minutes; type II power (400 Hz): 155 VAC, 0.17 seconds

Electromagnetic Interference:

MIL-STD-461C, Class A4, CS01, CS02, CS06 power leads; CE01, CE03, CE07 power leads

Leakage Current:

< 5 mA line to chassis, 115 VAC, 60 and 400 Hz

Input Power:

1490 Watts

Output Power:

+28 VDC @ 32A, +/-15 VDC @ 1 A, +5 VDC @ 5A, and -220 VDC @ .02A, for a total output power of approx. 1180W at 79% efficiency.

Shock:

MIL-STD-901D; Operating+/- 15 g, 11 mSec; Non-operating +/- 30 g

Temperature:

Operating: 0° C to +50° C; Non-operating -40° C to -70° C

Altitude:

Operating: 10,000 feet; Non-operating: 15,000 feet

Humidity:

95%, non-condensing

EMI/EMC:

MIL-STD-461C

Reliability (MTBF):

> 22,000 hours